BJJQR - YELLOW 8507

  • MSDS: BJJQR
  • Manufacturer: MARKEM CORP
  • Product Name: YELLOW 8507
  • National Stock Number: 7510-00N010782
Product Identification

Product ID:YELLOW 8507
MSDS Date:03/11/1986
FSC:7510
NIIN:00N010782
MSDS Number: BJJQR

Responsible Party
MARKEM CORPORATION
150 CONGRESS STREET
KEENE, NH 03431

Emergency Phone: 603-352-1130

Info Phone: 603-352-1130

Cage: 38360

Contractor
MARKEM CORPORATION
KEENE, NH 03431 US

Telephone: 603-352-1130

Cage: 38360

Ingredients

DIETHYLENE GLYCOL MONOBUTYL ETHER ACETATE

CAS: 124-17-4

RTECS: KJ9275000

Fraction By Weight: 10-25%

OSHA PEL N/K

ACGIH TLV: N/K


LEAD MOLYBDATE PIGMENT.(60% PB,10% CR,REST MO).ACGIH TLV

CAS: 12656-85-8

RTECS: QA4660000

Fraction By Weight: 10-40%

OSHA PEL 0.05 MG (PB)/M3

ACGIH TLV: 0.15 MG (PB)/M3


LEAD CHROMATE PIGMENT.OSHA PEL FOR LEAD,INORG

CAS: 1344-37-2

Fraction By Weight: 10-40%

OSHA PEL 0.05 MG (PB)/M3

ACGIH TLV: 0.15 MG (PB)/M3

Hazards

LD50 LC50 Mixture:N/K
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:USE OF THIS PRODUCT IS REGULATED BY
OSHA LEAD STANDARD (29CFR1910.1025).REPEATED & PROLONGED EXPOSURE
MAY CAUSE DELAYED EFFECTS INVOLVING THE
BLOOD,GASTROINTESTINAL,NERVOUS & REPRODUCTIVE SYSTEMS.
Explanation of Carcinogenicity:CR & CERTAIN CR CMPD:KNOWN HUM CARC
(NTP,1984).LEAD CMPD,INORG:INAD EVID FOR CARC IN HUMANS;SUFF EVID
FOR CARC (SUP DA)
Effects of Overexposure:EYES:MODERATE
IRRITATION,REDNESS,TEARING.SKIN:SLIGHT
IRRITATION.INGESTION:IRRITATION,NAUSEA,VOMITING,DIARRHEA.INHALATION
:IRRITATION,WEAKNESS,DIZZINESS,FATIGUE,NAUSEA,HEADACHE.
Medical Cond Aggravated by Exposure:N/K

First Aid

First Aid:EYES:FLUSH WITH WATER FOR AT LEAST 15 MINUTES.CALL A
PHYSICIAN IMMEDIATELY.SKIN:WASH W/ SOAP & WATER.LAUNDER CONTAM
CLOTHING BEFORE REUSE.GET MEDICAL ATTENTION.INGESTION:IF
CONSCIOUS,GIVE TWO GLASSES OF WATER & INDUCE VOMITING.GET MEDICAL
ATTENTION IMMEDIATELY.INHALATION:REMOVE TO FRESH AIR.BEGIN
RESUSCITATION.GET MEDICAL ATTENTION.

Fire Fighting

Flash Point:237F,113.89C
Extinguishing Media:DRY CHEMICAL,CO*2,ALCOHOL FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:VAPORS ARE HEAVIER THAN AIR & MAY TRAVEL
ALONG GROUND & MAY BE IGNITED AT DISTANT LOCATIONS.HAZARDOUS
DECOMPOSITION PRODUCTS:CO,CO*2,LEAD & CHROMIUM COMPOUNDS.

Accidental Release

Spill Release Procedures:ELIMINATE ALL SOURCES OF IGNITION.ABSORB
SPILLED MATERIAL WITH VERMICULITE OR FLOOR ABSORBENT.
Neutralizing Agent:N/K

Handling

Handling and Storage Precautions:N/K
Other Precautions:N/K

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL AND GENERAL VENTILATION NECESSARY TO KEEP AIR
CONCENTRATION BELOW EXPOSURE OF CONCERN .
Protective Gloves:RUBBER (LATEX OR NEOPRENE).
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:N/K
Work Hygienic Practices:LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
EXPLAN OF CARCIN:IN ANIMALS (IARC,1987).CR(VI)CMPD:INAD EVID FOR CARC
IN HUMANS;SUFF EVID FOR CARC IN ANIMALS (IARC,1987).ROUTES OF
ENTRY:INGESTION .

Chemical Properties

Boiling Pt:B.P. Text:N/K
Melt/Freeze Pt:M.P/F.P Text:N/K
Decomp Temp:Decomp Text:N/K
Vapor Pres:VERY LOW
Vapor Density:N/K
Spec Gravity:N/K
Evaporation Rate & Reference:VERY SLOW
Solubility in Water:NEGLIGIBLE
Appearance and Odor:YELLOW INK,MILD ODOR.
Percent Volatiles by Volume:<1

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES,STRONG MINERAL ACIDS.
Stability Condition to Avoid:HEAT AND FLAME.
Hazardous Decomposition Products:CO,CO*2,LEAD & CHROMIUM COMPOUNDS.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISP MUST BE IN ACCORDANCE W/ FEDERAL,STATE &
LOCAL REGS .UNDER RCRA,IT IS RESPONSIBILITY OF GENERATOR TO
DETERMINE IF WASTE MEETS FEDERAL,STATE HAZ WASTE CRITERIA
(USES,MIXS,PROCESSES,ETC MAY R ENDER MATL HAZ).CONSULT AUTHORITIES
FORINFO.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.